Back to Companypage
Business Logo
 
  • Konzern
    • About us
    • Management
    • Press
    • Events
    • Employees
    • Careers
    • Sponsoring
  • Business Units
    • Analytical Instrumentation
    • Life Science
    • Optics
  • Produkte
    • Products from A to Z
  • Investor | Media Relations
    • Key Figures
    • Share
    • Financial Reports
    • Annual Document
    • Corporate Governance
    • Ad Hoc Announcements
    • Director’s Dealings
    • Annual General Meeting
    • Financial Calendar
    • Press Releases
Analytical Instrumentation
  • Philosophy
  • Company Profile
  • References
  • History
  • Products
    • Atomic Spectrometry
    • Molecular Spectroscopy
    • Sum Parameters (TOC/TN | TOX)
      • TOC | TN Analysis
      • AOX | TOX | TX Analysis
      • Automation | Accessories
    • Elemental Analysis
    • Antioxidants | Free radicals
  • Service | Support
  • Events
  • Press Center
  • Contact

Sign in

  • AJ International |
  • Languages
    • English
    • Deutsch
    • Español
    • Français
    • Русский
    • 日本語
 

back to Sum Parameters

TOC | TN Analysis

multi N/C®- series – the right analyzer for every application

ANJ_Product_Icons_multinc-kurz

The multi N/C® series is the powerful family of instruments with a convincing overall concept for the fully automatic and simultaneous analysis of total carbon and total nitrogen TN from every sample.

ANJ_Product_Icons_VitaANJ_Product_Icons_EasyCalANJ_Product_Icons_UVANJ_Produkt_Icons_Focus_11-09-02

  • multi N/C 2100
  • multi N/C 3100
  • multi N/C UV HS
  • multi N/C pharma
space

multi N/C 2100

The compact power pack!

The multi N/C® 2100 is the space-saving TOC/TNb analyzer which demonstrates its strength particularly in the field of environmental analysis. Along with VITA®, the FR NDIR-Detector and catalytic hightemperature
combustion up to 950°C, multi N/C® 2100 is equipped with a perfect injection technique for particlecontaining
samples.
The integrated autosampler and the solid technique turn it into a compact routine analyzer.

 

Characteristics multi N/C® 2100:

  • Focus Radiation NDIR-Detector
  • VITA® Flow Management System*
  • Easy Cal*
  • Auto-protection
  • Catalytic high-temperature oxidation up to 950°C
  • Valve-free direct-injection technology
  • Suitable also for small injection volumes
  • Upgradable for simultaneous TNb determination
  • A catalyst for simultaneous TOC/TNb determination in the entire measurement range
  • Option of HT 1300 or double furnace technology for solid analysis
  • Compact system with integrated, fully automated autosampler
*model-specific
 
space

multi N/C 3100

Versatility at the highest level!

No matter whether ultra-pure water or waste water, multi N/C® 3100 is suitable for all samples. This is made
possible by the combination of catalytic high-temperature combustion, VITA®, the Focus Radiation NDIR-Detector, as well as flow injection with intelligent rinsing technology for particle-containing samples.
In addition, multi N/C® 3100 is particularly fast and thus permits high sample throughputs.

 

Characteristics multi N/C® 3100:

  • Focus Radiation NDIR-Detector
  • VITA® Flow Management System
  • Easy Cal
  • Auto-protection
  • Catalytic high-temperature oxidation up to 950°C
  • Flow injection with intelligent rinsing technology for particle-containing samples
  • Suitable for variable injection volumes
  • High sensitivity down to the lowest ppb range
  • Can be equipped for simultaneous TNb determination
  • A single catalyst for simultaneous TOC/TNb determination in the entire measurement range
  • High-temperature combustion (HTC) technology: HT 1300
  • High sample throughput by parallel purging and analyzing
  • Optionally available with autosamplers of different capacity
 
space

multi N/C UV HS

TOC-determination made easy!

The maintenance requirements of wet chemical TOC analyzers are very low. The multi N/C® UV HS is a system which works both with an oxidation agent (peroxodisulfate) and a highly effective UV radiation source for sample oxidation. At the same time the system is highly sensitive and suitable — along with ultra-pure water samples — also for drinking water or special samples, such as acids, electrolysis baths and other aggressive matrices.

Unlike classical TOC analyzers with an UV reactor, multi N/C® UV HS uses two wavelengths instead of just one: 254 nm and 185 nm. The hard radiation obtained in this way guarantees a complete oxidation of even the most stable carbon compounds. The effective blank value reduction by means of automated purging of the reagents ensures minimal system blank values. For ultra-pure water analyses, a decisive advantage
can be to work only with UV radiation, without oxidation agents, because the blank value of the oxidation agent can cause interference in the trace analysis. This is not a problem with multi N/C® UV HS! A suitable method can be selected in the user interface, so that the High Power UV reactor delivers the necessary energy for complete oxidation.

 

Characteristics multi N/C® UV HS:

  • Focus Radiation NDIR-Detector
  • VITA® Flow Management System
  • Easy Cal
  • Auto-protection
  • Wet chemical oxidation with a High Power UV reactor
  • Flow injection
  • High-precision dosing unit for variable, in particular very high injection volumes
  • Maximum sensitivity and precision in the ppb area
  • Effective blank value reduction
  • TOC determination also in aggressive matrices
  • High-temperature combustion (HTC) technology: HT 1300
  • High sample throughput by parallel purging and analyzing
  • Optionally available with autosamplers of different capacity
 
space

multi N/C pharma

Designed for the pharmaceutical industry!

Pharmaceutical applications require special technological solutions: highest sensitivity and precision as well as adaptation to the requirements of the pharmaceutical industry.

multi N/C® pharma has been designed especially for pharmaceutical applications. Two models are available: multi N/C® pharma HT and multi N/C® pharma UV.

Depending on the application, two digestion principles are available: catalytic high-temperature combustion up to 950°C (multi N/C® pharma HT) or wet chemical oxidation in a High Power UV reactor (multi N/C® pharma UV). At the same time, the focus is on the precision and correctness of the measurement results in the lower measurement range. This is possible thanks to the VITA® Flow Management System and by high sample injection volumes with the help of a high-precision injection syringe. And also by the use of a volume-specific calibration method which can be used to perform reliable calibration down to the lower ppb range.

Minimal system blank values are obtained through the automatic purging of the used chemicals. In addition, a blank value free digestion without reagents is available. multi N/C® pharma is thus uniquely suitable for ultra-pure water analyses, in particular for the analysis of WFI (water for injection purposes), AP (purified water), liquid or solid samples (swabs) from the cleaning validation and other typical applications in the pharmaceutical labs.

 

The Self Check System (SCS) provides valuable services in a pharmaceutical lab

All important device parameters are continuously checked and any deviations are recorded in the audit trail. The System Suitability Test (SST), which is necessary in the FDA, is an integrated function of the multiWin® software and can be performed completely automatically by pressing a button.

System Suitability Test (SST)

Saccharose and p-benzoquinone are both provided at a concentration of 500 μg/l and measured. Certified ready-touse solutions are available for this purpose. The user interface offers an integrated SST function which can be executed intuitively by the user and the obtained result is then saved in the audit trail.

Highest levels of precision and correctness in the ppb range

This is achieved by means of the highly sensitive Focus Radiation NDIR-Detector®, VITA® and the unique
volume-specific calibration method. This method can be used for calibration down to the lower ppb range by injection of different volumes using just a single standard. This means that the trace range, in which it is particularly difficult to prepare stable calibration standards, can be reliably calibrated for the first time.

IQ, OQ, PQ and SST — a completely reliable package!

multi N/C® pharma provides detailed IQ, OQ and PQ documents that have been especially optimized for the
pharmaceutical industry. The device performs a strict mandatory test program during installation. After the
device test has been completed, you will receive the software validation certificate, the detailed SST report and much more.

Characteristics multi N/C® pharma:

  • Focus Radiation NDIR-Detector
  • VITA® Flow Management System
  • Easy Cal
  • Auto-protection

 

  • Available either for catalytic high-temperature oxidation up to 950°C (multi N/C® pharma HT) or wet chemical oxidation with High Power UV reactor (multi N/C® pharma UV)
  • Flow injection
  • High-precision dosing unit for variable, in particular very high injection volumes
  • Maximum sensitivity and precision in the ppb range
  • Effective blank value reduction — excellent for applications in the trace range
  • Unique volume-specific calibration down to the lowest measurement range
  • Swab test module* for applications in the cleaning validation
  • Integrated SST function
  • Detailed, pharmaceutical industry-specific documents (IQ/OQ/PQ etc. )
  • Can be equipped for simultaneous TNb determination*
  • One catalyst for simultaneous TOC/TNb determination
  • Available either for HT 1300 or double furnace technology for solid analysis*
  • High sample throughput by means of parallel purging and analyzing
  • Optionally available with autosamplers of different capacity
* model-specific
 

top

 
AJ Blomesystem GmbH | AJ Cybertron GmbH | AJ Innuscreen GmbH
AJ Roboscreen GmbH | AJZ Engineering GmbH | Biometra GmbH | CyBio AG
Analytik Jena AG | Contact | Imprint | Conditions of Use | Privacy Policy | Sitemap